Touch - Indoor Air Quality Monitor
Touch - Indoor Air Quality Monitor
Touch - Indoor Air Quality Monitor
Touch - Indoor Air Quality Monitor
Touch - Indoor Air Quality Monitor
Touch - Indoor Air Quality Monitor
Touch - Indoor Air Quality Monitor
Touch - Indoor Air Quality Monitor
Touch - Indoor Air Quality Monitor

Touch - Indoor Air Quality Monitor

Regular price
$209.00
Sale price
$209.00

The PurpleAir Touch is our personal air quality monitor.

Designed for indoor use, it rests comfortably on any surface in your home or office. Highly visible LEDs provide AQI information at a glance, easily viewable from across a room. Utilize its double-tap feature to cycle through brightness levels and connect it to WiFi to see its real-time PM2.5 data on the interactive map, accessible by any smart device.

NOTICE: Power adapter NOT included; find a suitable option here.

Quantity must be 1 or more
Shipping calculated at checkout.

  • New Generation PurpleAir indoor particulate sensor with multi-colored LED ring
  • Tap sensor for adjusting LED brightness, double tap the sensor to adjust LED brightness.
  • Single Laser Particle Counter (PMS-1003)
  • Pressure, Temperature, Humidity & Gas Sensor (BME688)
  • WiFi connectivity with data stored in the cloud
Dimensions 4.25 in x 3 in x 2.25 in (108 mm x 67 mm x 57 mm)
Color Translucent white with real-time US EPA AQI multi-colored LED ring
Power requirements 5V USB Micro, 0.18A continuous, 600mA peak
Power cord length 3.2ft (1m) USB (Type A)
Intended Use Indoor use only
WiFi Yes
Expansion Port Yes
Internal Storage No
Warranty One (1) year limited warranty
Tap sensor for adjusting LED brightness, double tap the sensor to adjust LED brightness.
Manufacturer Kionix, Inc.
Model Number KX122-1037
Temperature range -40°F to 185°F (-40°C to 85°C)
Mechanical Shock (powered and unpowered) 5,000g for 0.5ms
10,000g for 0.2ms
Laser Particle Counters

Class 1 Laser. A Class 1 laser is safe under all conditions of normal use.

Manufacturer Plantower
Type PMS-1003
Range of measurement 0.3, 0.5, 1.0, 2.5, 5.0, & 10 μm
Counting efficiency 50% at 0.3μm & 98% at ≥0.5μm
Effective range
(PM2.5 standard)*
0 to 500 μg/m³
Maximum range (PM2.5 standard)* ≥1000 μg/m³
Maximum consistency error (PM2.5 standard) ±10% at 100 to 500μg/m³ & ±10μg/m³ at 0 to 100μg/m³
Standard Volume 0.1 liter
Single response time ≤1 second
Total response time ≤10 seconds
Pressure, Temperature, Humidity, & Gas Sensor
Manufacturer BOSCH
Model Number BME688
Temperature range -40°F to 185°F (-40°C to 85°C)
Pressure range 300 to 1100 hPa
Humidity Response time (τ63%): 8s
Accuracy tolerance: ±3% RH
Hysteresis: ≤1.5% RH
Gas Response time (τ33-63%): <1s
Resolution: ±0.08%
Wireless

Contains Transmitter Module FCC ID: 2AC7Z-ESPWROOM02D

Wireless Networks 802.11b/g/n @ 2.4GHz
(WPA2 pre-shared key or open networks)
Certificates FCC/CE/TELEC/SRRC
Tx Power 802.11 b: +20 dBm
802.11 g: +17 dBm
802.11 n: +14 dBm
Rx Sensitivity 802.11 b: -91 dbm (11 Mbps)
802.11 g: -75 dbm (54 Mbps)
802.11 n: -72 dbm (MCS7)
Antenna Type 2 dBi on-board PCB antenna

FCC Compliance Statement (Part 15.19)

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

Warning (Part 15.21)

Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

FCC Interference Statement (Part 15.105 (b))

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

To comply with FCC/IC RF exposure limits for general population / uncontrolled exposure, the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.

Customer Reviews

Based on 45 reviews
58%
(26)
9%
(4)
13%
(6)
9%
(4)
11%
(5)
G
Gary McDonald

Touch - Indoor Air Quality Monitor

D
David G
Great product but difficult to connect

We love the Touch’s color-coded air quality alerts and sleek look for indoor use. But it’s very difficult to establish Wi-Fi connectivity with the PurpleAir service. Most 2.4GHz devices are much easier to bring online.

A
Angie
I love having thsi indoor monitor

I have had this monitor since Aug 2021. I also have an outdoor monitor. Besides being helpful during fire season, the indoor monitor lets me know when cooking in the kitchen or burning candles or incense is impacting indoor air quality. I have an electric stove and using my cast iron pan always makes the air quality poor but I would have never known because the kitchen never seems smoky. One change I would make is to allow the user to turn of the light indicator, without turning off the device. I have a small place and overnight guests in the living room can't have a completely dark environment unless I unplug it. Otherwise the monitor is always on and is one of the many little lights on different applicances that seem to be ubiquitous these days.

D
Dr. Sarkawt Hama
Data resolution

We have got many types of sensors and all measured every ONE MINUTE, but the purple air is rubish and give only 2-minutes!!!!

Hello,

We apologize that you have had a poor experience with us. We've sent you an email in regard to this issue.

B
Bruce Cuthbert
Purple Air review

Purple Air monitor has been very helpful to track monitor local air quality concerns for forest fire smoke, etc.
I am using my PurpleAir monitor in conjunction with Paku app which opens up the data to alerts, widgets and additional info profiling.
This builds on the excellent info on the Purple air map and detailed graphs. The device was easy to setup and to use. I recommend the Paku app to augment the basic provided functionality.